smart delay with & without function?
hi there!
firstOall... neeo is the best remote in design and haptics i´ve ever had in my hands.
i really do not like the missing of IR CODE LEARNING... why?
now my problem....
i use actually 3 recipes
((FIRE TV)) ((ALL OFF)) (( TV ))
the fire tv has this program:
tv toggle ON - WAIT for 13 Sec (WITH SMART DELAY active) - input hdmi4 -
show control TV
the TV has this program:
tv toggle ON - WAIT for 13 Sec (WITH SMART DELAY active) - input hdmi1 - show control SAT
If the tv is switched on and i have TV active and activate ((FIRE TV)) neeo performs the smart delay perfect... no waiting (tv is on...) so direct switch to hdmi4.
But if i want to activate now ((TV)) it doesnt switch direct to the hdmi1 ...
it handles the macro (sorry recipe ;o) ) like the tv is shut down... it waits the full 13 seconds to switch to the hdmi1...
WHY?...
thanx best
claudio